= '''<span style="font-size: 10pt;">T</span><span lang="EN-US" style="font-size: 10pt;">urbine/Generator</span>'''  =
 
= '''<span style="font-size: 10pt;">T</span><span lang="EN-US" style="font-size: 10pt;">urbine/Generator</span>'''  =
  
'''<u><br></u>'''<u></u>'''<span lang="EN-US" style="font-size: 10pt;">The turbine will extract energy from the flowing</span>''' water, and turn it into mechanical energy that turns the generator to create electrical energy. System efficiencies range between 65% and 80% depending upon the turbine style and design.&nbsp;&lt;o:p&gt;&lt;/o:p&gt;
+
'''<u><br></u>''''''<span lang="EN-US" style="font-size: 10pt;">The turbine will extract energy from the flowing</span>''' water, and turn it into mechanical energy that turns the generator to create electrical energy. System efficiencies range between 65% and 80% depending upon the turbine style and design.&nbsp;  
 +
 
 +
<br>
 +
 
 +
<br>
 +
 
 +
= <!--[if gte mso 10]>
 +
<style>
 +
/* Style Definitions */
 +
table.MsoNormalTable
 +
{mso-style-name:"Normale Tabelle";
 +
mso-style-parent:"";
 +
font-size:10.0pt;"Times New Roman","serif";
 +
mso-fareast-"Times New Roman";}
 +
</style>
 +
<![endif]--><!--[if gte mso 9]><xml>
 +
 +
</xml><![endif]--><!--[if gte mso 9]><xml>
 +
 +
 
 +
</xml><![endif]--> '''<span>Microhydro-Electric</span> System Types'''  =
 +
 
 +
== '''Off-Grid Battery-Based Microhydro-Electric Systems'''  ==
 +
 
 +
<span>Most small off-grid hydro systems are battery-based. Battery systems have great flexibility and can be
 +
combined with other energy sources, such as wind generators and solar-electric
 +
arrays, if the stream is seasonal. Because stream flow is usually consistent,
 +
battery charging is as well, and it´s often possible to use a relatively small
 +
battery bank. Instantaneous demand (watts) will be limited not by the water
 +
potential or turbine, but by the size of the inverter.</span>
 +
 
 +
<span>The following illustration includes the primary
 +
components of any off-grid battery-based microhydro-electric system..</span>
 +
 
 +
picture... <br> &nbsp;
 +
 
 +
== '''Off-Grid Batteryless Microhydro-Electric Systems'''  ==
 +
 
 +
<span>If the stream has enough potential, one may decide to
 +
go with an AC-direct system. This consists of a turbine generator that produces
 +
AC output at 120 or 240 volts, which can be sent directly to standard household
 +
loads. The system is controlled by diverting energy in excess of load requirements
 +
to dump loads, such as water- or air-heating elements. This technique keeps the
 +
total load on the generator constant. A limitation of these systems is that the
 +
peak or surge loads cannot exceed the output of the generator, which is
 +
determined by the stream´s available head and flow. This type of system needs
 +
to be large to meet peak electrical loads, so it can often generate enough
 +
energy for all household needs, including water and space heating.</span>
 +
 
 +
<span>The following illustration includes the primary components
 +
of any off-grid batteryless microhydro-electric system. </span>
 +
 
 +
<!--[if gte vml 1]>
 +
 +
 
 +
 +
 
 +
 +
 
 +
 +
 
 +
 +
<![endif]-->picture ....
 +
 
 +
<br>
 +
 
 +
&nbsp;
 +
 
 +
== '''Grid-Tied Batteryless Microhydro-Electric Systems'''  ==
 +
 
 +
<span>Systems of this type use a turbine and controls to
 +
produce electricity that can be fed directly into utility lines. These can use
 +
either AC or DC generators. AC systems will use AC generators to sync directly
 +
with the grid. An approved interface device is needed to prevent the system
 +
from energizing the grid when the grid is out of action and under repair. DC
 +
systems will use a specific inverter to convert the output of a DC hydro
 +
turbine to grid-synchronous AC. The biggest drawback of batteryless systems is
 +
that when the utility is down, your electricity will be out too. When the grid
 +
fails, these systems are designed to automatically shut down.</span>
 +
 
 +
<span>The following illustration includes the primary
 +
components of any grid-tied batteryless microhydro-electric system. </span>
 +
 
 +
<!--[if gte vml 1]>
 +
 +
 
 +
 +
 
 +
 +
 
 +
 
 +
 +
 
 +
 +
 
 +
 +
 
 +
 +
<![endif]-->&nbsp;
 +
 
 +
[[|]]'''<span>Microhydro-Electric</span>''' System Components
 +
 
 +
'''Controls'''<span>
 +
</span>
 +
 
 +
AKA: Charge controller, controller, regulator
 +
 
 +
<!--[if gte vml 1]>
 +
 +
 +
<![endif]-->[[Image:|Controller]]
 +
 
 +
&nbsp;
 +
 
 +
<span>The function of a
 +
charge controller in a hydro system is equivalent to turning on a load to
 +
absorb excess energy. Battery-based microhydro systems require charge
 +
controllers to prevent overcharging the batteries. Controllers generally send
 +
excess energy to a secondary (dump) load, such as an air or water heater. Unlike
 +
a solar-electric controller, a microhydro system controller does not disconnect
 +
the turbine from the batteries. This could create voltages that are higher than
 +
some components can withstand, or cause the turbine to&nbsp;overspeed, which could result in dangerous
 +
and damaging overvoltages.</span>
 +
 
 +
<span>Off-grid, batteryless
 +
AC-direct microhydro systems need controls too. A load-control governor
 +
monitors the voltage or frequency of the system, and keeps the generator
 +
correctly loaded, turning dump-load capacity on and off as the load pattern
 +
changes, or mechanically deflects water away from the runner. Grid-tied
 +
batteryless AC and DC systems also need controls to protect the system if the
 +
utility grid fails.</span>
 +
 
 +
== '''Dump Load'''  ==
 +
 
 +
AKA: diversion load, shunt load
 +
 
 +
<!--[if gte vml 1]>
 +
 +
 +
<![endif]-->[[Image:|Dump Load 1]]<!--[if gte vml 1]>
 +
 +
 +
<![endif]-->[[Image:|Dump Load 2]]
 +
 
 +
<span>A dump
 +
load is an electrical resistance heater that must be sized to handle the full
 +
generating capacity of the microhydro turbine. Dump loads can be air or water
 +
heaters, and are activated by the charge controller whenever the batteries or
 +
the grid cannot accept the energy being produced, to prevent damage to the
 +
system. Excess energy is "shunted" to the dump load when necessary.</span>
 +
 
 +
&nbsp;
 +
 
 +
&nbsp;
 +
 
 +
== '''<span>Battery</span> Bank'''  ==
 +
 
 +
AKA: storage battery
 +
 
 +
<!--[if gte vml 1]>
 +
 +
 +
<![endif]-->[[Image:|Battery Bank]]
 +
 
 +
<span>By using
 +
reversible chemical reactions, a battery bank provides a way to store surplus
 +
energy when more is being produced than consumed. When demand increases beyond
 +
what is generated, the batteries can be called on to release energy to keep
 +
your household loads operating.</span>
 +
 
 +
<span>A
 +
microhydro system is typically the most gentle of the RE systems on the
 +
batteries, since they do not often remain in a discharged state. The bank can
 +
also be smaller than for a wind or PV system. One or two days of storage is
 +
usually sufficient. Deep-cycle lead-acid batteries are typically used in these
 +
systems. They are cost effective and do not usually account for a large
 +
percentage of the system cost.</span>
 +
 
 +
&nbsp;
 +
 
 +
== '''Metering'''  ==
 +
 
 +
<span>AKA:
 +
battery monitor, amp-hour meter, watt-hour meter</span>
 +
 
 +
<!--[if gte vml 1]>
 +
 +
 +
<![endif]-->[[Image:|Metering]]
 +
 
 +
<span>System
 +
meters measure and display several different aspects of your
 +
microhydro-electric system´s performance and status—tracking how full your
 +
battery bank is, how much electricity your turbine is producing or has
 +
produced, and how much electricity is being used. Operating your system without
 +
metering is like running your car without any gauges—although possible to do,
 +
it´s always better to know how well the car is operating and how much fuel is
 +
in the tank.</span>
 +
 
 +
&nbsp;
 +
 
 +
[[|]]'''<span>Main DC</span>''' Disconnect
 +
 
 +
== '''AKA: Battery/Inverter disconnect'''  ==
 +
 
 +
<!--[if gte vml 1]>
 +
 +
 +
<![endif]-->[[Image:|Main DC Disconnect]]
 +
 
 +
<span>In
 +
battery-based systems, a disconnect between the batteries and inverter is
 +
required. This disconnect is typically a large, DC-rated breaker mounted in a
 +
sheet-metal enclosure. It allows the inverter to be disconnected from the
 +
batteries for service, and protects the inverter-to-battery wiring against
 +
electrical faults.</span>
 +
 
 +
&nbsp;
 +
 
 +
&nbsp;
 +
 
 +
== '''Inverter'''  ==
 +
 
 +
<span>AKA: DC-to-AC
 +
converter </span>
 +
 
 +
<!--[if gte vml 1]>
 +
 +
 +
<![endif]-->[[Image:|Battery-Based Inverter]]<span>Inverters
 +
transform the DC electricity stored in your battery bank into AC electricity
 +
for powering household appliances. Grid-tied inverters synchronize the system´s
 +
output with the utility´s AC electricity, allowing the system to feed
 +
hydro-electricity to the utility grid. Battery-based inverters for off-grid or
 +
grid-tied systems often include a battery charger, which is capable of charging
 +
a battery bank from either the grid or a backup generator if your creek isn´t
 +
flowing or your system is down for maintenance.</span>
 +
 
 +
<span>In rare
 +
cases, an inverter and battery bank are used with larger, off-grid AC-direct
 +
systems to increase power availability. The inverter uses the AC to charge the
 +
batteries, and synchronizes with the hydro-electric AC supply to supplement it
 +
when demand is greater than the output of the hydro generator.</span>
 +
 
 +
[[|]]'''<span>AC</span>''' Breaker Panel
 +
 
 +
AKA: mains panel, breaker box, service entrance
 +
 
 +
<!--[if gte vml 1]>
 +
 +
 +
<![endif]-->[[Image:|AC Breaker Panel]]
 +
 
 +
<span>The AC
 +
breaker panel, or mains panel, is the point at which all of a home´s electrical
 +
wiring meets with the provider of the electricity, whether that´s the grid or a
 +
microhydro-electric system. This wall-mounted panel or box is usually installed
 +
in a utility room, basement, garage, or on the exterior of a building. It
 +
contains a number of labeled circuit breakers that route electricity to the various
 +
rooms throughout a house. These breakers allow electricity to be disconnected
 +
for servicing, and also protect the building´s wiring against electrical fires.</span>
 +
 
 +
<span>Just like
 +
the electrical circuits in your home or office, a grid-tied inverter´s
 +
electrical output needs to be routed through an AC circuit breaker. This
 +
breaker is usually mounted inside the building´s mains panel. It enables the
 +
inverter to be disconnected from either the grid or from electrical loads if
 +
servicing is necessary. The breaker also safeguards the circuit´s electrical
 +
wiring.</span>
 +
 
 +
'''&nbsp;'''
 +
 
 +
[[|]]'''Kilowatt-Hour Meter'''
 +
 
 +
<span>AKA: KWH
 +
meter, utility meter</span>
 +
 
 +
<!--[if gte vml 1]>
 +
 +
 +
<![endif]-->[[Image:|Kilowatt-Hour Meter]]
 +
 
 +
<span>Most
 +
homes with grid-tied microhydro-electric systems will have AC electricity both
 +
coming from and going to the utility grid. A multichannel KWH meter keeps track
 +
of how much grid electricity you´re using and how much your RE system is
 +
producing. The utility company often provides intertie-capable meters at no
 +
cost.</span>
 +
 
 +
'''&nbsp;'''
 +
 
 +
'''&nbsp;'''
 +
 
 +
'''&nbsp;'''
 +
 
 +
'''&nbsp;'''
 +
 
 +
'''&nbsp;'''
 +
 
 +
'''&nbsp;'''
 +
 
 +
== ''''Turbines'types'''  ==
 +
 
 +
<span><!--[if gte vml 1]>
 +
 +
 +
<![endif]-->[[Image:]]</span>
 +
 
 +
<span>A turbine converts the energy in
 +
falling water into shaft power. There are various types of turbine which can be
 +
categorised in one of several ways. The choice of turbine will depend mainly on
 +
the pressure head available and the design flow for the proposed hydropower
 +
installation. As shown in table 2 below, turbines are broadly divided into
 +
three groups; high, medium and low head, and into two categories: impulse and
 +
reaction. </span>
 +
 
 +
{| cellpadding="0" border="1"
 +
|-
 +
| valign="top" align="center" colspan="4" |
 +
'''<span>Head</span> '''
 +
 
 +
'''pressure'''
 +
 
 +
|-
 +
| valign="top" |
 +
'''<span>Turbine</span> '''
 +
 
 +
'''Runner'''
 +
 
 +
| valign="top" align="center" |
 +
'''High'''
 +
 
 +
| valign="top" align="center" |
 +
'''Medium'''
 +
 
 +
| valign="top" align="center" |
 +
'''Low'''
 +
 
 +
|-
 +
| valign="top" |
 +
Impulse
 +
 
 +
| valign="top" |
 +
<span>Pelton
 +
</span>
 +
 
 +
Turgo
 +
 
 +
Multi-jet Pelton <br>
 +
 
 +
| valign="top" |
 +
<span>Crossflow
 +
</span>
 +
 
 +
Turgo
 +
 
 +
Multi-jet Pelton <br>
 +
 
 +
| valign="top" |
 +
Crossflow
 +
 
 +
|-
 +
| valign="top" |
 +
Reaction
 +
 
 +
| valign="top" |
 +
<span>Francis
 +
</span>
 +
 
 +
Pump-as-turbine (PAT) <br>
 +
 
 +
| valign="top" |
 +
<span>Propeller
 +
</span>
 +
 
 +
Kaplan <br>
 +
 
 +
| valign="top" |
 +
&nbsp;  
 +
 
 +
|}
 +
 
 +
'''&nbsp;'''
 +
 
 +
<span>The difference between impulse and
 +
reaction can be explained simply by stating that the ''impulse'' turbines
 +
convert the kinetic energy of a jet of water in air into movement by striking
 +
turbine buckets or blades - there is no pressure reduction as the water
 +
pressure is atmospheric on both sides of the impeller. The blades of a ''reaction''
 +
turbine, on the other hand, are totally immersed in the flow of water, and the
 +
angular as well as linear momentum of the water is converted into shaft power -
 +
the pressure of water leaving the runner is reduced to atmospheric or lower. </span>
 +
 
 +
== '''Load factor'''  ==
 +
 
 +
<span>The load factor is the amount of
 +
power used divided by the amount of power that is available if the turbine were
 +
to be used continuously. Unlike technologies relying on costly fuel sources,
 +
the 'fuel' for hydropower generation is free and therefore the plant becomes
 +
more cost effective if run for a high percentage of the time. If the turbine is
 +
only used for domestic lighting in the evenings then the plant factor will be
 +
very low. If the turbine provides power for rural industry during the day,
 +
meets domestic demand during the evening, and maybe pumps water for irrigation
 +
in the evening, then the plant factor will be high. </span>
 +
 
 +
<span>It is very important to ensure a
 +
high plant factor if the scheme is to be cost effective and this should be
 +
taken into account during the planning stage. Many schemes use a 'dump' load
 +
(in conjunction with an electronic load controller - see below), which is
 +
effectively a low priority energy demand that can accept surplus energy when an
 +
excess is produced e.g. water heating, storage heaters or storage cookers. </span>
 +
 
 +
== '''Load control governors'''  ==
 +
 
 +
<span>Water turbines, like petrol or
 +
diesel engines, will vary in speed as load is applied or relieved. Although not
 +
such a great problem with machinery which uses direct shaft power, this speed
 +
variation will seriously affect both frequency and voltage output from a
 +
generator. Traditionally, complex hydraulic or mechanical speed governors
 +
altered flow as the load varied, but more recently an electronic load
 +
controller (ELC) has been developed which has increased the simplicity and
 +
reliability of modern micro-hydro sets. The ELC prevents speed variations by
 +
continuously adding or subtracting an artificial load, so that in effect, the
 +
turbine is working permanently under full load. A further benefit is that the
 +
ELC has no moving parts, is very reliable and virtually maintenance free. The
 +
advent of electronic load control has allowed the introduction of simple and
 +
efficient, multi-jet turbines, no longer burdened by expensive hydraulic
 +
governors.&nbsp;</span>
  
 
[[Category:Hydro]]
 
[[Category:Hydro]]

Revision as of 15:37, 29 June 2009

Turbine/Generator

'
'
The turbine will extract energy from the flowing water, and turn it into mechanical energy that turns the generator to create electrical energy. System efficiencies range between 65% and 80% depending upon the turbine style and design. 



Microhydro-Electric System Types

Off-Grid Battery-Based Microhydro-Electric Systems

Most small off-grid hydro systems are battery-based. Battery systems have great flexibility and can be combined with other energy sources, such as wind generators and solar-electric arrays, if the stream is seasonal. Because stream flow is usually consistent, battery charging is as well, and it´s often possible to use a relatively small battery bank. Instantaneous demand (watts) will be limited not by the water potential or turbine, but by the size of the inverter.

The following illustration includes the primary components of any off-grid battery-based microhydro-electric system..

picture...
 

Off-Grid Batteryless Microhydro-Electric Systems

If the stream has enough potential, one may decide to go with an AC-direct system. This consists of a turbine generator that produces AC output at 120 or 240 volts, which can be sent directly to standard household loads. The system is controlled by diverting energy in excess of load requirements to dump loads, such as water- or air-heating elements. This technique keeps the total load on the generator constant. A limitation of these systems is that the peak or surge loads cannot exceed the output of the generator, which is determined by the stream´s available head and flow. This type of system needs to be large to meet peak electrical loads, so it can often generate enough energy for all household needs, including water and space heating.

The following illustration includes the primary components of any off-grid batteryless microhydro-electric system.

picture ....


 

Grid-Tied Batteryless Microhydro-Electric Systems

Systems of this type use a turbine and controls to produce electricity that can be fed directly into utility lines. These can use either AC or DC generators. AC systems will use AC generators to sync directly with the grid. An approved interface device is needed to prevent the system from energizing the grid when the grid is out of action and under repair. DC systems will use a specific inverter to convert the output of a DC hydro turbine to grid-synchronous AC. The biggest drawback of batteryless systems is that when the utility is down, your electricity will be out too. When the grid fails, these systems are designed to automatically shut down.

The following illustration includes the primary components of any grid-tied batteryless microhydro-electric system.

 

[[|]]Microhydro-Electric System Components

Controls

AKA: Charge controller, controller, regulator

[[Image:|Controller]]

 

The function of a charge controller in a hydro system is equivalent to turning on a load to absorb excess energy. Battery-based microhydro systems require charge controllers to prevent overcharging the batteries. Controllers generally send excess energy to a secondary (dump) load, such as an air or water heater. Unlike a solar-electric controller, a microhydro system controller does not disconnect the turbine from the batteries. This could create voltages that are higher than some components can withstand, or cause the turbine to overspeed, which could result in dangerous and damaging overvoltages.

Off-grid, batteryless AC-direct microhydro systems need controls too. A load-control governor monitors the voltage or frequency of the system, and keeps the generator correctly loaded, turning dump-load capacity on and off as the load pattern changes, or mechanically deflects water away from the runner. Grid-tied batteryless AC and DC systems also need controls to protect the system if the utility grid fails.

Dump Load

AKA: diversion load, shunt load

[[Image:|Dump Load 1]][[Image:|Dump Load 2]]

A dump load is an electrical resistance heater that must be sized to handle the full generating capacity of the microhydro turbine. Dump loads can be air or water heaters, and are activated by the charge controller whenever the batteries or the grid cannot accept the energy being produced, to prevent damage to the system. Excess energy is "shunted" to the dump load when necessary.

 

 

Battery Bank

AKA: storage battery

[[Image:|Battery Bank]]

By using reversible chemical reactions, a battery bank provides a way to store surplus energy when more is being produced than consumed. When demand increases beyond what is generated, the batteries can be called on to release energy to keep your household loads operating.

A microhydro system is typically the most gentle of the RE systems on the batteries, since they do not often remain in a discharged state. The bank can also be smaller than for a wind or PV system. One or two days of storage is usually sufficient. Deep-cycle lead-acid batteries are typically used in these systems. They are cost effective and do not usually account for a large percentage of the system cost.

 

Metering

AKA: battery monitor, amp-hour meter, watt-hour meter

[[Image:|Metering]]

System meters measure and display several different aspects of your microhydro-electric system´s performance and status—tracking how full your battery bank is, how much electricity your turbine is producing or has produced, and how much electricity is being used. Operating your system without metering is like running your car without any gauges—although possible to do, it´s always better to know how well the car is operating and how much fuel is in the tank.

 

[[|]]Main DC Disconnect

AKA: Battery/Inverter disconnect

[[Image:|Main DC Disconnect]]

In battery-based systems, a disconnect between the batteries and inverter is required. This disconnect is typically a large, DC-rated breaker mounted in a sheet-metal enclosure. It allows the inverter to be disconnected from the batteries for service, and protects the inverter-to-battery wiring against electrical faults.

 

 

Inverter

AKA: DC-to-AC converter

[[Image:|Battery-Based Inverter]]Inverters transform the DC electricity stored in your battery bank into AC electricity for powering household appliances. Grid-tied inverters synchronize the system´s output with the utility´s AC electricity, allowing the system to feed hydro-electricity to the utility grid. Battery-based inverters for off-grid or grid-tied systems often include a battery charger, which is capable of charging a battery bank from either the grid or a backup generator if your creek isn´t flowing or your system is down for maintenance.

In rare cases, an inverter and battery bank are used with larger, off-grid AC-direct systems to increase power availability. The inverter uses the AC to charge the batteries, and synchronizes with the hydro-electric AC supply to supplement it when demand is greater than the output of the hydro generator.

[[|]]AC Breaker Panel

AKA: mains panel, breaker box, service entrance

[[Image:|AC Breaker Panel]]

The AC breaker panel, or mains panel, is the point at which all of a home´s electrical wiring meets with the provider of the electricity, whether that´s the grid or a microhydro-electric system. This wall-mounted panel or box is usually installed in a utility room, basement, garage, or on the exterior of a building. It contains a number of labeled circuit breakers that route electricity to the various rooms throughout a house. These breakers allow electricity to be disconnected for servicing, and also protect the building´s wiring against electrical fires.

Just like the electrical circuits in your home or office, a grid-tied inverter´s electrical output needs to be routed through an AC circuit breaker. This breaker is usually mounted inside the building´s mains panel. It enables the inverter to be disconnected from either the grid or from electrical loads if servicing is necessary. The breaker also safeguards the circuit´s electrical wiring.

 

[[|]]Kilowatt-Hour Meter

AKA: KWH meter, utility meter

[[Image:|Kilowatt-Hour Meter]]

Most homes with grid-tied microhydro-electric systems will have AC electricity both coming from and going to the utility grid. A multichannel KWH meter keeps track of how much grid electricity you´re using and how much your RE system is producing. The utility company often provides intertie-capable meters at no cost.

 

 

 

 

 

 

'Turbines'types

[[Image:]]

A turbine converts the energy in falling water into shaft power. There are various types of turbine which can be categorised in one of several ways. The choice of turbine will depend mainly on the pressure head available and the design flow for the proposed hydropower installation. As shown in table 2 below, turbines are broadly divided into three groups; high, medium and low head, and into two categories: impulse and reaction.

Head

pressure

Turbine

Runner

High

Medium

Low

Impulse

Pelton

Turgo

Multi-jet Pelton

Crossflow

Turgo

Multi-jet Pelton

Crossflow

Reaction

Francis

Pump-as-turbine (PAT)

Propeller

Kaplan

 

 

The difference between impulse and reaction can be explained simply by stating that the impulse turbines convert the kinetic energy of a jet of water in air into movement by striking turbine buckets or blades - there is no pressure reduction as the water pressure is atmospheric on both sides of the impeller. The blades of a reaction turbine, on the other hand, are totally immersed in the flow of water, and the angular as well as linear momentum of the water is converted into shaft power - the pressure of water leaving the runner is reduced to atmospheric or lower.

Load factor

The load factor is the amount of power used divided by the amount of power that is available if the turbine were to be used continuously. Unlike technologies relying on costly fuel sources, the 'fuel' for hydropower generation is free and therefore the plant becomes more cost effective if run for a high percentage of the time. If the turbine is only used for domestic lighting in the evenings then the plant factor will be very low. If the turbine provides power for rural industry during the day, meets domestic demand during the evening, and maybe pumps water for irrigation in the evening, then the plant factor will be high.

It is very important to ensure a high plant factor if the scheme is to be cost effective and this should be taken into account during the planning stage. Many schemes use a 'dump' load (in conjunction with an electronic load controller - see below), which is effectively a low priority energy demand that can accept surplus energy when an excess is produced e.g. water heating, storage heaters or storage cookers.

Load control governors

Water turbines, like petrol or diesel engines, will vary in speed as load is applied or relieved. Although not such a great problem with machinery which uses direct shaft power, this speed variation will seriously affect both frequency and voltage output from a generator. Traditionally, complex hydraulic or mechanical speed governors altered flow as the load varied, but more recently an electronic load controller (ELC) has been developed which has increased the simplicity and reliability of modern micro-hydro sets. The ELC prevents speed variations by continuously adding or subtracting an artificial load, so that in effect, the turbine is working permanently under full load. A further benefit is that the ELC has no moving parts, is very reliable and virtually maintenance free. The advent of electronic load control has allowed the introduction of simple and efficient, multi-jet turbines, no longer burdened by expensive hydraulic governors.